English/Spanish Handy Transformer Ratio Tester 3 Phase Turns Ratio Group Meter
Product Overview:This new JH2711 Handheld Transformer Tatio Tester TTR Metet has a host that is easy to measure at high altitudes, more convenient to use, and has more stable functions. The host comes with a printer that can print data at any time.For the power system, transformers are the core equipment in the system, so the long-term and reliable operation of transformers will be related to the stability and reliability of the entire system. Before the newly installed transformer is put into operation and in accordance with the preventive testing regulations of State Grid, it is required to conduct regular turns ratio or voltage ratio tests on the operating transformer. The traditional variable ratio bridge operation is cumbersome, the reading is not intuitive, and necessary conversions need to be made. The test result is only the value of one phase change ratio. This transformer ratio tester overcomes the shortcomings of traditional ratio bridge testing. The screen adopts a large high-resolution LCD display screen, which is convenient for on-site use. It has a Chinese menu prompt function, easy and intuitive operation, and can complete three-phase ratio testing in one go. The testing speed is fast and the accuracy is high. Product Features: 1. The three-phase CNC sine inverter power supply output has soft start and soft stop functions, so the testing speed is fast and the accuracy is high.2. Three phase transformer, single-phase transformer, PT, CT, Z-type transformer ratio, group, polarity testing function.3. CT ratio polarity testing function.4. It has angle difference testing function during single-phase testing.5. The tap changer can be tested up to 99 gears.6. Wide testing range, up to 10000.7. High and low voltage reverse connection reminder.8. Output short circuit reminder.9. Non power-off clock and date display; The data storage method is local storage, with 100 test data pieces. The stored data can be transferred to a computer (PC);10.Thermal printer printing function.11. Small size, light weight, convenient for carrying and use.12.Handheld Host to be more easy to carry and the printer is in the host, could print data any more convenient . Technical parameters: Range0.8~10000Accuracy± (reading × 0.1%+2 words) (less than or equal to 1000)± (reading × 0.2%+2 words) (greater than 1000 but less than or equal to 3000)± (reading × 0.3%+2 words) (greater than 3000)Resolution Ratio0.9~9.9999(0.0001)10~99.999(0.001)100~999.99(0.01)1000~9999.9(0.1)10000(1)Workingpower supplyAC100-240V, 50/60Hz (battery charging voltage)Host weight1.8KgVolume280mm(L)×180mm(W)×80mm(H)Operating temperature-10℃~50℃Relative Humidity<90%, no condensation
LCR Meter LCR Component Tester LCR Tester 2.4″ TFT Color Screen Chinese English
Description LCR Meter LCR Component Tester LCR Tester 2.4″ TFT Color Screen Chinese English Description: The NJ series impedance tester adopts a high-performance processor and ultra-low power consumption design. It is a portable product mainly used to measure parameter performance of three basic components (resistance R, capacitance C, and inductance L). The product has a built-in large-capacity lithium-ion battery. It is small in size, light in weight, and easy to carry. It is more convenient to use for outdoor and high-altitude special operations. Display screen interface and buttons are clear and simple, at a glance, Chinese and English can be set by yourselves, easy to use and simple to operate. It is designed with online test function. Main Features: 1. Test frequency range is wide. 2. Small size, light weight, easy to carry. Appearance size: 130*108*31 (mm); net weight: 315g. 3. Built-in battery, using 2000mAH polymer lithium battery, continuous working time exceeds 8 hours. 4. High resolution, and measurement result is in 6-digit. 5. With calibration function, accurate measurement. 6. With online test function, cost-effective. 7. Serial/parallel mode, level and internal resistance are optional. 8. Strong anti-power frequency interference, and the interference level prompts. 9. Automatic gear shift, no manual pre-preparation is required. 10. Test level can be set arbitrarily. Specifications: – Product model: NJ100S (fixed frequency) – Power frequency: 50Hz. Frequency points: 15. Frequency point value: 50, 100, 600, 1000, 6000, 10000, 20000, 30000, 40000, 50000, 60000, 75000, 80000, 93750, 100000. – Power frequency: 60Hz. Frequency points: 13. Frequency point value: 60, 120, 600, 1200, 6000, 12000, 24000, 30000, 38400, 48000, 60000, 75000, 96000. – Measuring ranges: * Resistance: 0.2mΩ~500MΩ * Capacitance: 5fF~150mF * Inductance: 0.5nH~100kH – Product model: NJ101S- Working frequency: 50Hz~100KHz- Stepping: 50Hz~1KHz- Measuring ranges:* Resistance: 0.1mΩ~2000MΩ* Capacitance: 0.003pF~200mF* Inductance: 0.5nH~300kH – Product model: NJ200S- Working frequency: 50Hz~200KHz- Stepping: 10Hz~5KHz- Measuring ranges:* Resistance: 0.1mΩ~2000MΩ* Capacitance: 0.003pF~200mF* Inductance: 0.5nH~300kH – Product model: NJ300S- Working frequency: 50Hz~300KHz- Stepping: 10Hz~10KHz- Measuring ranges:* Resistance: 0.1mΩ~2000MΩ* Capacitance: 0.003pF~200mF* Inductance: 0.5nH~300kH – Display: 2.4″ TFT, resolution 320×240 (QVGA) – Battery capacity: 2000mAH (7.4Wh) – Power consumption: <1W – Charging current: 400mA – Charging port: USB (only as a charging port) – Automatic shutdown: always on, immediately off, 5 minutes ~ 60 minutes (optional) – Measurement parameters: Rs/Xs/Rp/Xp/Cs/Cp/Ls/Lp; |Z|/D/Q/θ/Vrms/Irms – DC bias: None – Display resolution: 6 digits effective value – Measuring speed: online (NJ100S does not have this function), fast, medium, slow – Measurement accuracy: <0.5‰ (within impedance 100mΩ~200MΩ) – Accuracy: <1‰ – Display range: * |Z|, R, X: 0.00001mΩ~9999999MΩ * C: 0.00001pF~9999999F * L: 0.00001nH~9999999H * D, Q: 0.001~99999 * θ (Degrees): -179.9 to 179.9 * Vrms: 0.0001mV~999999mV * Irms: 0.0001nA~999999mA – Level (mVrms): arbitrarily set (1~1000, step 1) -Output impedance: 30Ω, 100Ω (optional) – Model: automatic, series, parallel (optional) – DUT: Automatic, resistance, inductance, capacitance, electrolysis (optional) – Calibration function: open circuit, short circuit (with factory value), load calibration – Appearance size: 130*108*31(mm) – Net weight: 315g – Working temperature: 5℃~40℃ – Atmospheric pressure: 860hPa~1060hPa Functions Overview: – This product has three basic interfaces: measurement, calibration, and system interfaces. The "Measurement" and "Calibration" interfaces also have sub-interfaces. By default, it will enter the main measurement interface when it turns on. – It can easily measure the impedance of about 1mΩ. For example, a wire of 1cm generally has about 6mΩ. – The impedance of 300MΩ can be easily measured, and the actual measurement is 20GΩ. See the pictures below for details. The LCR bridges on the market basically cannot measure such a large impedance. Package Included: – 1 x Set of LCR Meter Note: – Components and other items pictured are not included, for demonstration purposes only. Thank you for your understanding! Precautions: 1. In order to ensure the accuracy of measurement and calibration, please warm up the product for at least 5 minutes before measuring. Especially when doing calibration, it is best to warm up for more than 20 minutes. After warming up, calibration parameters can be more accurate. 2. When powered by a battery, the internal noise of the product is the smallest, so it is recommended to measure under battery power. Especially when doing the calibration operation, it is strongly recommended to do it under battery power supply. When a charger is connected, if the quality of your charger is not good, a certain amount of noise will be generated. 3. Do not connect to a computer's USB charging port for charging. The signal from the USB port will seriously interfere with the working state of the product and cause serious inaccuracy in product measurement. 4. Please try to use better quality fixtures. 5. Before measurement and calibration, please make sure that there is no strong interference signal around, so as not to cause inaccurate measurement results due to interference. 6. When the battery is low, please charge it in time to avoid long-term lack of power. 7. The interface is BNC. Since copper has relatively lower strength than other metals, please try to protect it carefully to avoid falling and bumping damage. 8. In the case of strong interference, unconventional operation, and abnormal software unknown bugs, a crash may occur (the power may be consumed after the crash, until the battery is exhausted). At this time, please directly press the "RESET" hole to reset the product to avoid damage to the battery. If the battery is exhausted and the battery is extremely short of power, the current will be large during charging, and the charger with a small power supply current will have short-circuit protection, but please continue to charge until the battery can be charged normally. 9. When the power is lower than 15%, it will not be able to turn on; when the power is very low, the system will automatically shut down. Please charge in time. 10. When measuring large capacitances (uF level), the "electrolysis" item is more accurate than the "capacitance" item. 11. The device under test cannot be charged, especially the energy storage device (such as electrolytic capacitor), it must be discharged before testing, otherwise it may It will damage the instrument. 12. When measuring milliohm-level devices, if more accurate is required, please perform short-circuit calibration again under the same conditions as the frequency to be measured. 13. When calibrating, try to stay away from the surrounding environment interference, preferably away from the mains, such as wires and sockets. When measuring, use the battery of the instrument to work, do not plug in the USB port for power supply. Payment Terms 1.We accept PayPal only. 2.All major credit cards are accepted through secure payment processor PayPal. 3.Payment must be received within 7 business days of auction closing. 4.We ship to your eBay or Paypal address. Please make sure your eBay and Paypal address is correct before you pay.Shipping Terms – For remote regions, we will charge your extra shipping costs. Usually it cost about 35USD-50USD. We will contact you after your payment. Thanks for your understanding.Return Terms 1. If you receive defective item, please kindly notify us within 14 days. We will guide you the returning instruction for replacement or refund. 2. If you purchased in improper condition, please NOTE that the sipping and handling fee will not be refund, all return shipping fee should paid by the buyer unless item DOA. 3. We reserve the right to refuse any returns for objective reasons.Custom Duties & Taxes 1. Import duties, taxes, and charges are not included in the item price or postage cost. These charges are the buyer's responsibility. 2. Avoiding some unnecessary trouble, please check with your country's customs office to inform us what we should declare its value before shipping.Feedback 1. If you are dissatisfied for any reason, please don't be quick to leave us neutral or negative feedback. We work hard to make sure EVERY CUSTOMER 100% SATISFIED and resolve any problem for you and always leave positive feedback to all our customers. 2. If you are satisfied with the product you received, please kindly leave us a positive feedback and 5 star DSR. If there is any problem of your order, please feel free to contact us firstly, we are responsible and credible seller, will follow it for you asap. On Oct-28-20 at 01:16:34 PDT, seller added the following information:
New 5.0MP USB Iriscope Iris Analyzer Iridology Camera with Iris English Software
It is the iridologist’s primary tool for examination and evaluation and evaluation of the case itself. What is a digital iris?. ▪ Accurate and fast display of iris status. ▪ Support 1X, 30X iris, 50X skin, 200X hair lens.
Stanley Premium Aluminum Rafter Square (English)
Extra-thick aircraft-grade aluminum maximizes durability. Individually inspected for accuracy. Embossed graduations are painted yellow for readability in all light conditions. Surface treated to resist corrosion and extend the life.
The Emicol 2 Range Volt Meter Untested English Made
Condition Reasonable Untested.
Greentest Eco 4 Nitrate Tester Radiation Geiger Counter English Dosimeter
The results were applied to test algorithms which have been coded into the Greentest device. If you insert a place, pull it out and insert it, you may get different results. There are fluctuations.
LCR-TC2 Upgraded Version of High Precision Transistor Tester V2.3E English&Cable
Get The Right At The Right Price!. We will be happy to resolve any issues you may have in a cordial and friendly manner.
Leica GEOSYSTEMS DNA03/DNA10 USER MANUAL English Binder
The Leica GEOSYSTEMS DNA03/DNA10 USER MANUAL English Binder is a comprehensive manual designed for users of Leica products. This manual provides detailed information on how to operate and troubleshoot the DNA03/DNA10 models, ensuring users have all the necessary guidance at their fingertips. With clear instructions and diagrams, this manual helps users maximize the performance and lifespan of their Leica equipment, making it an essential tool for professionals in the field of surveying and geospatial technology.
LA1010 USB Logic Analyzer 16 Input Channels 100MHz with The English PC Software
✅ High-Performance 16-Channel Logic Analyzer: Cost-effective LA1010 USB logic analyzer with 16 input channels and 100MHz sampling rate per channel, featuring portable design and included KingstVIS PC software.
(NOT IN ENGLISH) Keyence CV-3000 96M1704 USERS MANUAL #131G24PR7
Thanks for looking. Message if any question