Elitech RC-5 USB Reusable Temperature Data logger Temp Recorder Quick PDF Report
Large Capacity Up to 32,000 recording points. Keep recording for over 3 months at a 5-minute interval. Record interval: 10s~24h adjustable LCD Visual Display Over-temperature alarm & upper/lower limits can be set MAX/MIN values available Current date and time Recorded capacity 6-month Battery Life Up to 6-month battery life Adopting replaceable CR2032 Lithium battery Depending on optimal storage conditions of 15℃~23℃ / 45%RH to 74%RH Start & Stop Logging Press and hold the button for 5 seconds until the “Solid Triangle” icon or “Solid Square” icon shows on the screen, indicating the logger start/stop logging. Export Free Data Report from Software Connect the data logger to your computer and use ElitechLog software to save or export the data. Reset & Reuse the Logger Click “Quick Reset” to reset the orignal parameters settings. Disconnect the device from your computer to start using again. (Please see User Manual for more detailed instructions) Technical Specifications Temperature Measurement Range -30°C~+70°C(-22°F~158°F)* Temperature Accuracy ±0.5°C/±0.9°F(-20℃~+40°C); ±1°C/±1.8°F(others) Resolution 0.1℃/°F Memory Maximum 32000 points Start Mode Press button; Use software Stop Mode Press button; Use software; Auto stop Shelf Life 1 year Certification EN12830, CE, RoHS, FCC, WEEE Protection Grade IP67 Dimension 80*33.5*14 mm Weight 20g * * At ultralow temperature, the LCD will be slow but does not affect normal logging. It will be back to normal after the temperature rises. Free Elitechlog Software for Windows & macOS Meanings of the Setting Parameters: Log Clock: Not configurable. But the time will sync with that on the computer after our user clicks the Save Parameter button under the Parameter tab. S/N: Not configurable. Trip Description: Configurable. The info entered here will be shown on the report, it can be used to differentiate one logger from another. Log interval: Configurable. This means how often our user wants the logger to perform a reading, it can be 10S, 1minute, or 1day. Start Delay(H): Configurable. This means after you press the start button on the logger, how long it would wait to officially start logging. Press button: Configurable. This means after we press the start button for 4 seconds on the logger to start logging. Temperature Unit: Celsius or Fahrenheit Optional. High/low limit: Configurable. The upper and lower alarming point you want to set. RC-5 RC-5+ RC-5+ TE GSP-6 ISO 17025 Certified Record Capacity 32,000 Temperature Points 32,000 Temperature Points 32,000 Temperature Points 16,000 Temperature points, 16,000 Humidity points 32,000 Temperature Points Temperature Range -22℉~158℉(-30°C ~+70°C) -22℉~158℉(-30°C ~+70°C) -40°F to 185°F(-40°C ~+85°C) (External Sensor Only)) -40°F to 185°F(-40°C ~+85°C) -22℉~158℉(-30°C ~+70°C) Humidity Range NO NO NO 10%~90%RH NO Max. Battery Life 3-month 6-month 6-month 2-year 3-month Restart by Press Button NO ✓ ✓ NO NO Connection Type USB USB USB USB Cable USB Auto PDF Report NO ✓ ✓ NO NO Optional Password Protection NO ✓ ✓ NO NO Cyclic Recording NO NO NO ✓ NO Extra External Sensor NO NO ✓ NO NO
Elitech RC-5 USB Reusable Temperature Data logger Temp Recorder with PDF Report
Elitech RC-5 USB Reusable Temperature Data logger Temp Recorder with PDF Report Elitech RC-5 USB Reusable Temperature Data logger Temp Recorder with PDF Report Multi-use temperature data logger, 32,000 recording points, with wide measuring range -30℃~70℃ / -22℉~158℉. Up to 6 months battery life, replaceable battery, low power consumption. Built-in USB connector, no cable or reader required to download data or generate PDF report. Powerful LCD indication, easy to view temperature data, logged points, alarm status, and more key information, etc. Fahrenheit/Celsius switchable through free software. IP65 protection grade and temperature alarms, suitable to use on dry ice and vaccine storage, transportation and etc. PLEASE EMAIL/MESSAGE US FOR THE CALIBRATION CERTIFICATE. 24/7 US Technician Support via Email and Phone. Meanings of the Setting Parameters: Log Clock: Not configurable. But the time will sync with that on the computer after our user clicks the Save Parameter button under the Parameter tab. S/N: Not configurable. Trip Description: Configurable. The info entered here will be shown on the report, it can be used to differentiate one logger from another. Log interval: Configurable. This means how often our user wants the logger to perform a reading, it can be 10S, 1minute, or 1day. Start Delay(H): Configurable. This means after you press the start button on the logger, how long it would wait to officially start logging. Press button: Configurable. This means after we press the start button for 4 seconds on the logger to start logging. Temperature Unit: Celsius or Fahrenheit Optional. High/low limit: Configurable. The upper and lower alarming point you want to set. Shipping We will ship all items within 3 working days once payment finished, We always ship items by USPS First Class, FedEx is the Expedited Shipping choice. Sometimes international’s delivery is highly dependent on the courier company and local customs/duties. Import duties and taxes are not included in the item price or shipping charges. These charges are the buyer’s responsibility. About us How we got our start? Founded in 1996, Elitech is dedicated to researching and developing the manufacture of products for the frozen and refrigeration industry, providing remote solutions for the cold chain. What makes our product unique? The constant innovation and integration of resources make Elitech better and better at finding effective solutions, reduce costs, help customers and enhance competitiveness. Why we love what we do? Our core obligation is to provide an excellent experience to our customers, building a line of loyal and satisfied customers is what leads our company to a brighter future.